六、故障排除:故障排除troubleshooting
故障現(xiàn)象The fault phenomenon |
故障原因The cause of the problem |
排除方法 Elimination method |
無 電 源 顯 示 No electrical source display |
1.空氣開關(guān)控制開關(guān)未合上The air switch control switch is not closed 2.控制保險絲斷 The control fuse is blown 3.空氣開關(guān)或控制開關(guān)損壞Air switch or control switch damaged 4.其他原因 Other reasons |
1.合上開關(guān) Close the switch 2. 更換保險絲 Replace fuse 3. 更換 replace 4.與廠家聯(lián)系維修Contact the manufacturer for repair |
啟動不起來(即按啟動按鈕后,電流顯示為“0”,機(jī)器聲響很快,約幾秒又自動停止)Can not start up (that is, after pressing the start button, the current display is "0", the machine sounds very fast, and stops automatically in about a few seconds) |
1.感應(yīng)圈兩圈間短路Short circuit between induction rings 2.感應(yīng)圈連接頭松動Loose connection of induction coil 3.感應(yīng)圈接頭處有生料帶There is raw tape at the induction ring joint 4.設(shè)備故障Equipment failure |
1.整修感應(yīng)圈 Refit the induction ring 2.上緊感應(yīng)圈螺帽Tighten the induction ring nut 3.清除生料帶 Remove raw material strips 4.與廠家聯(lián)系維修Contact the manufacturer for repair |
可以啟動,有電流顯示但不加熱或加熱很慢Can be started, with current display but not heated or heated very slowly |
感應(yīng)圈兩圈間短路Short circuit between induction rings |
整修感應(yīng)圈 Refit the induction ring |
工作時報警Working alarm |
參見面板指示說明See panel instructions |
|
工作即報警,反復(fù)多次現(xiàn)象一樣Work that alarm, repeatedly many times |
設(shè)備故障Equipment failure |
與廠家聯(lián)系維修Contact the manufacturer for repair |